[HannoverMesse] Informing, Warning, Forwarding – Safe clean room monitoring with touch panels

Life-sciences companies must monitor their critical production processes with monitoring systems. This is about recording systems that have a high degree of data safety to record, transfer and save quality-relevant measuring data.
Professional providers of monitoring systems, as well as validation service providers offer systems that are aligned with GAMP 5 for this task. GAMP means Good Automated Manufacturing Practice; GAMP 5 is a quasi-standard that describes the requirements to setup and validation of computer-aided systems in a regulated pharmaceutics environment as a “guideline”.

[HannoverMesse] Informing, Warning, Forwarding – Safe clean room monitoring with touch panels
The clean room panel PUC 44 can (if desired) monitor and display more than just the classic climate data (pressure, temperature, moisture).

One important task of monitoring is making measured data visible in the locations where local decisions depend on them. The following examples are to make this clear:
Example 1: Only if the storage climate data are in an “OK range” may the staff perform refilling (otherwise, the quality of the product to be refilled may suffer).
Example 2: Only if the clean room has sufficient overpressure may the manlock be opened (otherwise, there would be the danger of contaminated air flowing in).
Example 3: Only if the particle concentration undercuts a threshold may the staff start a mixing process (otherwise, the product may be contaminated).
The current information (measured values and alarm situations) must be provided on site well visibly and unmistakably. At the same time, it must be avoided that the unauthorised user can change the monitoring system. Not least, the relevant measured values and alarm situations are not only to be displayed, but also forwarded to the superordinate system.
Measuring technology and clean room specialist halstrup-walcher now has put the perfect solution on the market for these requirements. Specifically, this is the multi-channel process panel PUC 44, which has a touch panel in the stainless steel frame. Several transmitters can be connected and supervised, both on site with the help of the display, and centrally in the monitoring system or BMS thanks to the integrated bus connection.
The clean room panel PUC 44 can (if desired) monitor and display more than just the classic climate data (pressure, temperature, moisture). Rather, it is possible to connect one to four analogue values per device. This may be, e.g., an oxygen concentration, a compressed air flow rate or a particle concentration – in the different processes, many different sensors may, after all, be of central importance.
On the other hand, the presentation of measured values does not have to be limited to alphanumeric information (value + unit). Where desired, the PUC 44 may also be parameterised with switchable views so that, e.g., pointer charts, bar charts and even curves (display of value development during the last minutes, hours or days) is possible.
In case of alarm, it must be shown at first glance what a measured value looks like. In the pharmaceutics environment, alarms in the sense of a traffic light function have become established for this:
If the signal of a sensor is in the forbidden range (below the alarm “LoLo” or above the alarm “HiHi”), a background colour that can be chosen by the customer (e.g. red) will be displayed.
For a warning, due to the sensor signal threatening to run out of the permitted range (i.e. signals below “Lo” or above “Hi”), a background colour that can be chosen by the customer will be displayed (e.g. yellow).
If the sensor value is OK, the background colour is not noticeable. A small bar chart in addition to the alphanumeric value shows how many percent of the defined measured range are currently utilised.
At the same time, it is often desired that the local staff will be informed of present problems by an acoustic alarm. The viewer is able to switch this warning sound off – confirmation in the monitoring system must, however, be reserved to the monitoring officer, who can solve the problem and at the same time is obliged to comment the event in the audit trail of the system. There deliberately is no confirmation option for the local user.
The transmission to the superordinate system (monitoring system or building management system) takes place via the integrated Modbus coupling. A BACnet coupling is already being prepared. In this respect, the clean room panel PUC 44 has the function of a gateway at the same time; this is an important contribution to low system costs.
Thanks to the GAMP 5-compliant password, the user is kept from any intervention on site apart from the browsing between released value views and deactivation of the acoustic alarm. The plant constructor or monitoring provider, in contrast, will be enabled to adjust each clean room panel PUC 44 to the respective application situation via a comfortable menu.
For best integration into the clean room wall, the clean room panel PUC 44 is delivered with two different stainless steel fronts. Both are installed in the clean room wall thanks to their low construction depth. Alternatively, a standard model (PUC 44-2) and a very high-quality very easy-to-clean model (PUC 44-3) are available. For installation sites outside of the clean room environment and the control cabinet fronts, a simple aluminium front version (PUC 44-3) can be used as well.
www.icnweb.co.kr

뉴스레터 구독하기

아이씨엔매거진은 AIoT, IIoT 및 피지컬 AI, 디지털트윈을 통한 제조업 디지털전환 애널리틱스를 제공합니다.
테크리포트: 자율제조, 전력전자, 모빌리티, 로보틱스, 스마트농업

AW2026 expo
ACHEMA 2027
전시회 세미나 선물 준비는 기프트랩스
오승모 기자
오승모 기자http://icnweb.kr
기술로 이야기를 만드는 "테크 스토리텔러". 아이씨엔 미래기술센터 수석연구위원이며, 아이씨엔매거진 편집장을 맡고 있습니다. 디지털 전환을 위한 데이터에 기반한 혁신 기술들을 국내 엔지니어들에게 쉽게 전파하는데 노력하는 중입니다.
fastech EtherCAT
as-interface
GiftLabs

Related Articles

Stay Connected

440FansLike
407FollowersFollow
224FollowersFollow
120FollowersFollow
372FollowersFollow
152SubscribersSubscribe
GiftLabs
spot_img
InterPACK
spot_img
SPS 2026
automotion
Power Electronics Mag

Latest Articles

Related Articles

PENGUIN Solutions
미뉴-노르딕, nRF54L15로 자산 추적 정밀도 혁신

미뉴-노르딕, nRF54L15로 자산 추적 정밀도 혁신

0
미뉴는 노르딕의 차세대 SoC를 통해 배터리 수명 10년과 고정밀 위치 추적을 동시에 구현함으로써, 대규모 산업 현장의 인프라 구축 및 유지보수 비용을 획기적으로 낮춘 자산 관리 솔루션을 완성했다
WindEnergy
InterPACK

Related Articles

fastech EtherCAT
as-interface
코보, 음전원 필요 없는 SOI 포트폴리오 발표… RF 제어 설계 간소화

코보, 음전원 필요 없는 SOI 포트폴리오 발표… RF 제어 설계 간소화

0
글로벌 반도체 기업 코보가 음전원 공급 장치 없이도 구동 가능한 차세대 RF 제어 칩셋 포트폴리오를 출시했다
인피니언, 업계 최초 205℃ 연속 동작 가능한 1300V SiC 모듈 공개

인피니언, 업계 최초 205℃ 연속 동작 가능한 1300V SiC 모듈 공개

0
인피니언이 기존보다 30°C 높은 205°C의 고온을 견디는 전기차 반도체 모듈을 선보여 차량 냉각 장치를 줄이고 무게를 가볍게 만들 수 있는 길을 열었다

개발자 밤샘 지옥 끝.. 노르딕 IoT 전주기 AI 지원 확장

0
노르딕 세미컨덕터가 사물인터넷 기기의 설계부터 실제 운영까지 전 과정을 인공지능으로 제어하는 기술을 도입하여 엔지니어들의 복잡한 오류 수정 업무를 대폭 축소했다
코보, 와이파이 AP에 UWB 통합… 전용 인프라 없는 고정밀 RTLS 시대 연다

코보, 와이파이 AP에 UWB 통합… 전용 인프라 없는 고정밀 RTLS 시대...

0
코보는 기존 기업용 와이파이 AP에 FiRa 및 옴록스 표준 UWB 기술을 통합하고 QPK3000 모듈을 출시함으로써, 인프라 중복 투자 비용을 제거한 경제적인 대규모 엣지 위치 추적 시장 선점에 나선다
마우저, 첨단 자동화를 위한 델타 48V 3상 전원공급장치 ‘포스-GT’ 공급

마우저, 첨단 자동화를 위한 델타 48V 3상 전원공급장치 ‘포스-GT’ 공급

0
마우저는 최대 96%의 고효율과 초슬림 설계를 갖춘 델타의 포스-GT 48V 전원공급장치를 공급하며, 보호 코팅과 광범위한 동작 온도를 지원해 전기차 충전 및 로보틱스 등 열악한 산업 환경의 전력 신뢰성을 높인다
ADI, 차세대 ‘A²B 2.0’ 양산… 케이블 경량화로 차량 연비 혁신 이끈다

ADI, 차세대 ‘A²B 2.0’ 양산… 케이블 경량화로 차량 연비 혁신 이끈다

0
ADI의 A²B 2.0은 배선 복잡도를 75% 줄이는 경량화 설계를 통해 차량 연비 경쟁력을 높이는 동시에, 고대역폭 이더넷 통합으로 SDV 시대의 프리미엄 오디오 인프라를 선점하고 있다
- Our Youtube Channel -Engineers Youtube Channel

Latest Articles