#하노버메세

[HannoverMesse] Informing, Warning, Forwarding – Safe clean room monitoring with touch panels

Life-sciences companies must monitor their critical production processes with monitoring systems. This is about recording systems that have a high degree of data safety to record, transfer and save quality-relevant measuring data.
Professional providers of monitoring systems, as well as validation service providers offer systems that are aligned with GAMP 5 for this task. GAMP means Good Automated Manufacturing Practice; GAMP 5 is a quasi-standard that describes the requirements to setup and validation of computer-aided systems in a regulated pharmaceutics environment as a “guideline”.

[HannoverMesse] Informing, Warning, Forwarding – Safe clean room monitoring with touch panels
The clean room panel PUC 44 can (if desired) monitor and display more than just the classic climate data (pressure, temperature, moisture).

One important task of monitoring is making measured data visible in the locations where local decisions depend on them. The following examples are to make this clear:
Example 1: Only if the storage climate data are in an “OK range” may the staff perform refilling (otherwise, the quality of the product to be refilled may suffer).
Example 2: Only if the clean room has sufficient overpressure may the manlock be opened (otherwise, there would be the danger of contaminated air flowing in).
Example 3: Only if the particle concentration undercuts a threshold may the staff start a mixing process (otherwise, the product may be contaminated).
The current information (measured values and alarm situations) must be provided on site well visibly and unmistakably. At the same time, it must be avoided that the unauthorised user can change the monitoring system. Not least, the relevant measured values and alarm situations are not only to be displayed, but also forwarded to the superordinate system.
Measuring technology and clean room specialist halstrup-walcher now has put the perfect solution on the market for these requirements. Specifically, this is the multi-channel process panel PUC 44, which has a touch panel in the stainless steel frame. Several transmitters can be connected and supervised, both on site with the help of the display, and centrally in the monitoring system or BMS thanks to the integrated bus connection.
The clean room panel PUC 44 can (if desired) monitor and display more than just the classic climate data (pressure, temperature, moisture). Rather, it is possible to connect one to four analogue values per device. This may be, e.g., an oxygen concentration, a compressed air flow rate or a particle concentration – in the different processes, many different sensors may, after all, be of central importance.
On the other hand, the presentation of measured values does not have to be limited to alphanumeric information (value + unit). Where desired, the PUC 44 may also be parameterised with switchable views so that, e.g., pointer charts, bar charts and even curves (display of value development during the last minutes, hours or days) is possible.
In case of alarm, it must be shown at first glance what a measured value looks like. In the pharmaceutics environment, alarms in the sense of a traffic light function have become established for this:
If the signal of a sensor is in the forbidden range (below the alarm “LoLo” or above the alarm “HiHi”), a background colour that can be chosen by the customer (e.g. red) will be displayed.
For a warning, due to the sensor signal threatening to run out of the permitted range (i.e. signals below “Lo” or above “Hi”), a background colour that can be chosen by the customer will be displayed (e.g. yellow).
If the sensor value is OK, the background colour is not noticeable. A small bar chart in addition to the alphanumeric value shows how many percent of the defined measured range are currently utilised.
At the same time, it is often desired that the local staff will be informed of present problems by an acoustic alarm. The viewer is able to switch this warning sound off – confirmation in the monitoring system must, however, be reserved to the monitoring officer, who can solve the problem and at the same time is obliged to comment the event in the audit trail of the system. There deliberately is no confirmation option for the local user.
The transmission to the superordinate system (monitoring system or building management system) takes place via the integrated Modbus coupling. A BACnet coupling is already being prepared. In this respect, the clean room panel PUC 44 has the function of a gateway at the same time; this is an important contribution to low system costs.
Thanks to the GAMP 5-compliant password, the user is kept from any intervention on site apart from the browsing between released value views and deactivation of the acoustic alarm. The plant constructor or monitoring provider, in contrast, will be enabled to adjust each clean room panel PUC 44 to the respective application situation via a comfortable menu.
For best integration into the clean room wall, the clean room panel PUC 44 is delivered with two different stainless steel fronts. Both are installed in the clean room wall thanks to their low construction depth. Alternatively, a standard model (PUC 44-2) and a very high-quality very easy-to-clean model (PUC 44-3) are available. For installation sites outside of the clean room environment and the control cabinet fronts, a simple aluminium front version (PUC 44-3) can be used as well.
www.icnweb.co.kr

뉴스레터 구독하기

아이씨엔매거진은 AIoT, IIoT 및 피지컬 AI, 디지털트윈을 통한 제조업 디지털전환 애널리틱스를 제공합니다.
테크리포트: 자율제조, 전력전자, 모빌리티, 로보틱스, 스마트농업

AW2026 expo
ACHEMA 2027
오승모 기자
오승모 기자http://icnweb.kr
기술로 이야기를 만드는 "테크 스토리텔러". 아이씨엔 미래기술센터 수석연구위원이며, 아이씨엔매거진 편집장을 맡고 있습니다. 디지털 전환을 위한 데이터에 기반한 혁신 기술들을 국내 엔지니어들에게 쉽게 전파하는데 노력하는 중입니다.
fastech EtherCAT
as-interface

Related Articles

Stay Connected

440FansLike
407FollowersFollow
224FollowersFollow
120FollowersFollow
372FollowersFollow
152SubscribersSubscribe
spot_img
InterPACK
spot_img
SPS 2026
automotion
Power Electronics Mag

Latest Articles

Related Articles

PENGUIN Solutions
구글, 엣지 AI 혁신 이끌 ‘젬마 4’ 공개… 온디바이스 추론 성능 극대화

구글, 엣지 AI 혁신 이끌 ‘젬마 4’ 공개… 온디바이스 추론 성능...

0
구글이 인터넷 연결 없이도 스마트폰이나 소형 산업용 컴퓨터에서 빠르게 작동하는 인공지능 '젬마 4'를 공개했다. 이 모델은 크기가 작으면서도 성능은 대형 AI 못지않아 공장의 기계 상태를 살피거나 로봇을 조종하는 데 유용하다
WindEnergy
InterPACK

Related Articles

fastech EtherCAT
as-interface
마우저, 진동 데이터를 클라우드로 직결하는 암페놀 ‘VDS130’ 공급

마우저, 진동 데이터를 클라우드로 직결하는 암페놀 ‘VDS130’ 공급

0
마우저가 공급하는 암페놀 VDS130은 기존 아날로그 진동 센서 자산을 유지하면서도 현장 데이터를 MQTT 클라우드로 즉시 연결해 주어, 산업 현장의 디지털 전환 비용과 시간을 획기적으로 줄여준다
피닉스컨택트, 유지보수·보안성 강화한 실외용 스마트 이더넷 박스 출시

피닉스컨택트, 유지보수·보안성 강화한 실외용 스마트 이더넷 박스 출시

0
피닉스컨택트가 실외에서 사용하는 똑똑한 통신 상자인 스마트 이더넷 박스를 업그레이드했다. 가장 큰 장점은 고장이 났을 때 복잡한 광케이블을 다시 연결할 필요 없이 상자 본체만 갈아 끼울 수 있어 복구 시간이 매우 짧다는 것
[#HM24] HARTING, 미래 핵심인 전기에너지에 열정을 쏟다

[#HM24] HARTING, 미래 핵심인 전기에너지에 열정을 쏟다

0
HARTING은 2024 하노버 박람회에서 TECO 2030 연료 전지에 사용되는 연결 기술을 소개한다
[#HM24] 안전한 데이터 교환의 상생적 이점

[#HM24] 안전한 데이터 교환의 상생적 이점

0
Roseman Labs의 솔루션은 실제 데이터의 개인 정보와 상업적 민감성을 보존하면서 여러 데이터 세트를 암호화, 연결 및 분석할 수 있도록 한다
P+F, LiDAR와 MEMS 결합한 산업용 3D 센서 개발

P+F, LiDAR와 MEMS 결합한 산업용 3D 센서 개발

0
P+F와 프라운호퍼 연구소는 지난 4월말 독일에서 개최된 하노버산업박람회(Hannover Messe 2023)에서 LiDAR와 MEMS 기술을 결합해 개발한 R3000 3-D LiDAR/MEMS 센서에 대한 연구 사례를 발표했다.
- Our Youtube Channel -Engineers Youtube Channel

Latest Articles