More

    [HannoverMesse] Informing, Warning, Forwarding – Safe clean room monitoring with touch panels

    Life-sciences companies must monitor their critical production processes with monitoring systems. This is about recording systems that have a high degree of data safety to record, transfer and save quality-relevant measuring data.
    Professional providers of monitoring systems, as well as validation service providers offer systems that are aligned with GAMP 5 for this task. GAMP means Good Automated Manufacturing Practice; GAMP 5 is a quasi-standard that describes the requirements to setup and validation of computer-aided systems in a regulated pharmaceutics environment as a “guideline”.

    The clean room panel PUC 44 can (if desired) monitor and display more than just the classic climate data (pressure, temperature, moisture).
    The clean room panel PUC 44 can (if desired) monitor and display more than just the classic climate data (pressure, temperature, moisture).

    One important task of monitoring is making measured data visible in the locations where local decisions depend on them. The following examples are to make this clear:
    Example 1: Only if the storage climate data are in an “OK range” may the staff perform refilling (otherwise, the quality of the product to be refilled may suffer).
    Example 2: Only if the clean room has sufficient overpressure may the manlock be opened (otherwise, there would be the danger of contaminated air flowing in).
    Example 3: Only if the particle concentration undercuts a threshold may the staff start a mixing process (otherwise, the product may be contaminated).
    The current information (measured values and alarm situations) must be provided on site well visibly and unmistakably. At the same time, it must be avoided that the unauthorised user can change the monitoring system. Not least, the relevant measured values and alarm situations are not only to be displayed, but also forwarded to the superordinate system.
    Measuring technology and clean room specialist halstrup-walcher now has put the perfect solution on the market for these requirements. Specifically, this is the multi-channel process panel PUC 44, which has a touch panel in the stainless steel frame. Several transmitters can be connected and supervised, both on site with the help of the display, and centrally in the monitoring system or BMS thanks to the integrated bus connection.
    The clean room panel PUC 44 can (if desired) monitor and display more than just the classic climate data (pressure, temperature, moisture). Rather, it is possible to connect one to four analogue values per device. This may be, e.g., an oxygen concentration, a compressed air flow rate or a particle concentration – in the different processes, many different sensors may, after all, be of central importance.
    On the other hand, the presentation of measured values does not have to be limited to alphanumeric information (value + unit). Where desired, the PUC 44 may also be parameterised with switchable views so that, e.g., pointer charts, bar charts and even curves (display of value development during the last minutes, hours or days) is possible.
    In case of alarm, it must be shown at first glance what a measured value looks like. In the pharmaceutics environment, alarms in the sense of a traffic light function have become established for this:
    If the signal of a sensor is in the forbidden range (below the alarm “LoLo” or above the alarm “HiHi”), a background colour that can be chosen by the customer (e.g. red) will be displayed.
    For a warning, due to the sensor signal threatening to run out of the permitted range (i.e. signals below “Lo” or above “Hi”), a background colour that can be chosen by the customer will be displayed (e.g. yellow).
    If the sensor value is OK, the background colour is not noticeable. A small bar chart in addition to the alphanumeric value shows how many percent of the defined measured range are currently utilised.
    At the same time, it is often desired that the local staff will be informed of present problems by an acoustic alarm. The viewer is able to switch this warning sound off – confirmation in the monitoring system must, however, be reserved to the monitoring officer, who can solve the problem and at the same time is obliged to comment the event in the audit trail of the system. There deliberately is no confirmation option for the local user.
    The transmission to the superordinate system (monitoring system or building management system) takes place via the integrated Modbus coupling. A BACnet coupling is already being prepared. In this respect, the clean room panel PUC 44 has the function of a gateway at the same time; this is an important contribution to low system costs.
    Thanks to the GAMP 5-compliant password, the user is kept from any intervention on site apart from the browsing between released value views and deactivation of the acoustic alarm. The plant constructor or monitoring provider, in contrast, will be enabled to adjust each clean room panel PUC 44 to the respective application situation via a comfortable menu.
    For best integration into the clean room wall, the clean room panel PUC 44 is delivered with two different stainless steel fronts. Both are installed in the clean room wall thanks to their low construction depth. Alternatively, a standard model (PUC 44-2) and a very high-quality very easy-to-clean model (PUC 44-3) are available. For installation sites outside of the clean room environment and the control cabinet fronts, a simple aluminium front version (PUC 44-3) can be used as well.
    www.icnweb.co.kr

    아이씨엔매거진
    ASI
    오승모 기자
    오승모 기자http://icnweb.kr
    기술로 이야기를 만드는 "테크 스토리텔러". 아이씨엔 미래기술센터 수석연구위원이며, 아이씨엔매거진 편집장을 맡고 있습니다. 디지털 전환을 위한 데이터에 기반한 혁신 기술들을 국내 엔지니어들에게 쉽게 전파하는데 노력하는 중입니다.
    • Mobile World Live
    • AW2025
    • 파스텍 배너 900
    • hilscher
    ASI

    Join our Newsletter

    Get the latest newsletters on industry innovations.

    AW2025
    MWC
    파스텍 배너 300
    오토모션
    embeddedworld 2025
    semicon 2025
    Hannover messe

    Related articles

    [#HM24] Siemens Unveils Generative AI-Powered Industrial Copilot

    The Siemens Industrial Copilot, the generative AI-powered assistant, is now seamlessly connected to the Totally Integrated Automation (TIA) Portal.

    [#HM24] 하노버메세 2024, 산업계의 새로운 시작을 제시하다

    "하노버 산업박람회 방문객들은 자동화, 인공 지능, 최첨단 드라이브 기술, 재생 에너지 및 수소를 현명하게 사용하는 방법에 대한 답을 찾고 있다. 하노버 메세(HANNOVER MESSE)의 전시업체들이 제공하는 것은 바로 이러한 종류의 전문 지식이다"

    [#HM24] 보쉬, 지속가능한 산업을 위한 8가지 하이라이트

    보쉬(Bosch)는 하노버 산업 박람회(Hannover Messe 2024)에서 공장 자동화·수소 경제·AI 위한 지속가능한 솔루션을 제시한다. 현장에서 지속가능한 산업 위한 8가지 하이라이트를 선보인다.

    기자의 추가 기사

    IIoT

    파스텍 배너 300
    파스텍 배너 300
    파스텍 배너 300

    추천 기사

    mobility