IIoT 기술 매거진 - 아이씨엔
Home » English News » HIMA delivers safety systems and fire&gas system for Ichthys gas field project (INPEX)

HIMA delivers safety systems and fire&gas system for Ichthys gas field project (INPEX)

Operated by INPEX, the Ichthys LNG project includes some of the world’s biggest and most advanced offshore facilities, massive onshore processing facilities near Darwin in the Northern Territory and an 890-kilometer pipeline to unite them.

HIMA was selected by the Ichthys joint venture to be the supplier for the safety instrumented systems (SIS) and the fire and gas system (F&G). The Ichthys LNG project consists of an LNG plant (onshore), a central processing facility (CPF) and a floating production storage and offloading (FPSO) vessel. The total order value is the largest HIMA has ever received for a single project.

When operational, the Ichthys LNG project is expected to produce 8.9 million tons of LNG and 1.6 million tons of LPG per annum, along with approximately 100,000 barrels of condensate per day at peak.

Ichthys LNG Project onshore facilities construction progress September

The SIS and F&G system are supplied using HIMax®, the first safety system designed to provide uninterrupted system operation throughout the entire life of the plant, while maximizing plant availability, productivity and safety. SIS/F&G systems using the HIMax® safety system hardware meet the requirements in accordance with AS/IEC 62061 and IEC 61326-3-1 (DIS).

The high-integrity pressure protection systems (HIPPS) rely on a Planar4 system which meets highest safety standards and can be used up to SIL 4 in accordance with IEC 61508. Onshore and offshore facilities and the pipeline are connected to around 25,000 safety I/O points, allocated in approximately 430 cabinets distributed via safeethernet, where applicable.

Besides the SIS/FGS/HIPPS, the HIMA scope of supply includes delivery of the pre-FID system development and standard application design and testing. The cybersecurity and network management with related hardware installation, the addressable fire system for the living quarters with the related detectors and the network management system for the SIS/F&G network complete the deliverables.

The HIMA hardware and firmware provided are certified up to SIL 3 according to AS/IEC 61508. HIMA will use the principles of AS/IEC 61511 in designing and testing the SIS and F&G system. The functional safety management (FSM) plan will be used to manage all stages of the design, implementation and manufacturing process.

이달의 추천기사 보기


추천 뉴스

B&R은 drinktec 2017 (홀 A3, 부스 328)에서 산업 등급의 서비스가 용이한 SuperTrak 수송 시스템을 선보일 예정이며, 이 시스템은 운송 및 포지셔닝중에 액체가 흐르는 것을 방지한다.

B&R, drinktec에서 빠르고 흐르지 않는 수송 기술 제시

SuperTrak으로 빠르고 유연한 필링(filling)라인 비앤드알(B&R)은 음료 및 액체 식품 생산자에게 탁월하고 다용도성을 갖춘 빠르고 흐르지 ...

이마트 첨담 물류센터 '네오 김포 센터 002'

이마트 온라인 물류센터 ‘네오 구리 센터 003’ 건립 무산

신세계 – 한국토지주택공사: 주민 민원에 계약 철회 합의 신세계 이마트가 건립을 구상중인 구리시 갈매지구 이마트 ...

답글 남기기

이메일은 공개되지 않습니다. 필수 입력창은 * 로 표시되어 있습니다.

hilscher